Vorteile im Überblick:
- Direktanschlusszähler für Hutschiene
- Nennspannung: 150 - 1000 V
- Referenzstrom lref: 130 A
- Maximaler Strom lmax: 650 A
- Datenformat/Protokoll: OCMF, kompatibel mit der S.A.F.E.-Transparenzsoftware
- 6TE breit
Technical characteristics:
Data sheet | DC Meter GSH01 |
Type | DIN-Rail DC meter for e-mobility, industrial and more.
Direct current meter according to German Eichrecht.
Calculation of compensated energy (line loss compensation by line resistance) |
Functional Features | - Transaction of energy registers
- OCMF - Open Charge Metering Format
- Compatible with S.A.F.E. transparency software
- Digital signature
- Configurable (duration, infotime registers)
- Calibration logbook
- Instantaneous readings
- High temperature 85°C
- High current 650A
- Sealable terminal cover |
Measuring mechanism parameters Voltage Umin
Umax | 150 V
1000 V |
Current Starting current (lst)
Minimum current (Imin)
Current (Itr)
Reference current (lref)
Maximum current (lmax) | 0.52 A
6.5 A
13 A
130 A
650 A |
Accuracy Class | Class B |
Measuring Active Energy One Energy Direction | +A with -A locking |
Energy Register Total Mains Energy
Transaction Device Energy | +A
+A |
Meter constant LED-Output | 1000 Imp/kWh, Total Mains Energy |
Display LCD
Display scope
Life cycle | with configurable backlight, configurable contents
Unit of the displayed value (kWh, kW, W, V, A, Ω)
> 12 Jahre |
Data interface RS485- Data Interface 1 and 2 Connector
Parameter | RJ12 ports
115.200 bps, 8N1 (settable) |
RS485- Data Interface 3 (communication with the charger station) Connector
Parameter
Communication Protocol | RJ12 port
115.200 bps, 8N1 (settable)
SLIP for Data Link Layer in OCMF format |
Power Consumption Voltage circuit
Current circuit
Auxiliary power supply | < 0.5 W at Un
< 0.04W/A*Imax
< 1 W |
Temperature Range Typical Operation
Storage | -40 °C to +80 °C -40 °C to +85 °C |
Environmental conditions Mechanical environmental conditions
Electromagnetic environmental conditions | M1
E2 |
Dimension Material | DIN-Rail 115.6 mm (L) x 107.2 mm (W) x 70.9 mm (H)
6 TE
fiber-glass reinforced Polycarbonate |
Storage Capacity for Start- and Stop-Charge Records
Capacity of Logbook | > 235.000
> 2.500 |
Weight | 550 g |
Inquiry